What Is Voltage Drop Calculator?
Voltage Drop Calculator is a free online tool by TechnSols that checks the voltage your cable loses. A cable is not a perfect wire. It has resistance of its own, and that resistance steals a little voltage on the way from the supply to the load. Over a short run the loss is tiny, but over a long garden cable, a solar panel run, or a feed to an outbuilding, the loss can be large enough that lights dim, motors struggle, and heaters give less heat than they should. Voltage Drop Calculator works out that cable voltage drop from the current, the one way cable length, the wire size and the metal, and shows it in volts, as a percent of the supply, and against the 5 percent limit electricians work to. The background is covered in the voltage drop article, which explains where the loss comes from and why it grows with length and current.
The tool fits the jobs where a cable run is long enough to matter. An electrician sizing a feed to a shed needs to know whether 2.5 square millimetre cable is enough or whether 4 square millimetre is needed. A solar installer needs the drop between the panels and the inverter kept low so the harvest is not wasted as heat in the cable. A camper running a 12 volt fridge on a long lead needs to know why the fridge cuts out even though the battery reads full. In each case the answer decides the cable size, and the cost of a larger cable is small beside the cost of a circuit that does not work.
How To Use Voltage Drop Calculator
There are only three steps. Enter the current and the length, pick the cable, and read the result that appears live on the page.
Enter Current And Cable Length
Type the current the load draws in amps, and the one way length of the cable run in metres. The length is the distance from the supply to the load, not the total wire in the run, because the tool counts the out and back wires itself. If the run is measured in feet, Length Converter changes it into metres first.
Pick The Cable And The Supply
Choose the wire size from the list, from 1.5 to 10 square millimetres, then pick copper or aluminium, then pick the supply voltage. Copper loses less than aluminium for the same size, and a bigger cross section loses less than a smaller one, so the choices matter as much as the length. If the load is rated in watts rather than amps, Unit Converter helps with the units before you start.
Read And Copy The Result
The result shows live as you type, with no button to press. When the current and length are filled, you see the drop in volts, the voltage drop percentage, the 5 percent limit in volts, and a plain verdict on whether the run passes. A worked example helps: 10 amps over 30 metres of 2.5 square millimetre copper on a 230 volt supply gives “Voltage drop: 4.03 V”, “1.75% of a 230 V supply”, “5% limit: 11.5 V”, “Within the 5% limit.” The Copy result button copies all of that in one go, ready to paste into a note or a quote. If the load power is what you know, Power Converter changes it between watts, kilowatts and horsepower.
That is the whole job. Two numbers and three choices in, one clear answer out, and the answer updates the moment you change anything, so you can see at once how a larger cable would fix an over limit run.
Why Use A Voltage Drop Calculator?
A cable that is too small for its run wastes energy as heat and starves the load. These are the reasons the check comes before the cable is bought.
Long Runs Lose The Most
Voltage drop grows directly with length, so a cable that is fine across a room can be far too small across a garden. Doubling the length doubles the loss, and the loss also grows with the current, so a long run to a heavy load is where the problem bites hardest. The calculation shows the loss before the cable is buried or clipped in place.
Low Voltage Starves Loads
Motors draw more current when the voltage falls, which heats them and shortens their life. Heaters give less heat. LED drivers and chargers can cut out or flicker. Keeping the drop under 5 percent keeps the load close to the voltage it was designed for, and the equipment lasts as it should.
Bigger Cable Is Cheaper Than Rework
Stepping up one cable size costs a little more copper at the start, but pulling a cable out and fitting a larger one after the job is finished costs far more in time and disruption. The calculation takes a minute and settles the size with confidence, so the right cable goes in the first time.
What Can You Do With Voltage Drop Calculator?
The result is a drop in volts with a percent beside it, but the uses around it are practical and everyday. These are the ones people come back for.
Size A Cable For An Outbuilding
A feed to a shed, garage or workshop runs tens of metres, and the drop decides the size. Work out the load current, type the length, and try the sizes in turn until the verdict reads within the limit. The smallest size that passes is the one to buy. To see the loss as a share of the supply, Percentage Calculator turns any part into a percent of the whole.
Compare Copper And Aluminium
An aluminium cable costs less than copper, but it loses about two thirds more voltage for the same size, because its resistivity is higher. Run the same numbers with each metal and compare the two verdicts, then weigh the saving against the larger size aluminium needs to pass. For the energy lost as heat in the cable, Energy Converter turns power and time into watt hours.
Find Why A Load Underperforms
A heater that feels weak or a pump that runs hot may be suffering a drop nobody measured. Type the real current and the real cable length, and the tool shows whether the cable is the cause. If the drop is over the limit, a larger cable is the fix, not a bigger load. For the mean of several meter readings, Average Calculator works it out from any list you type.
Voltage Drop Calculator Quality And Settings
The tool is built to be exact and honest. It uses the standard resistivity values, it counts both wires of the circuit, and it never changes a number you typed.
- Two metals: copper at 1.68 times 10 to the power minus 8 ohm metres, and aluminium at 2.82 times 10 to the power minus 8 ohm metres, so the comparison is honest.
- Five wire sizes: 1.5, 2.5, 4, 6 and 10 square millimetres, the sizes most often used for final circuits and sub mains.
- Three supply voltages: 120, 230 and 400 volts, so the same tool covers homes, workshops and three phase feeds.
- Live result: the drop, the percent and the verdict appear as you type, with no Convert button and no Calculate button to press.
- Copy the result: the Copy result button copies the drop, the percent, the limit and the verdict in one go, ready to paste anywhere.
If a field is empty, the tool shows the plain status “Enter the current and the cable length.” instead of guessing a number. That way you never see a result built on a missing value.
How Voltage Drop Calculator Works
The tool runs entirely in your browser. The voltage drop formula is simple: it works out the resistance of one wire from its resistivity, its length and its cross section, doubles it for the out and back wires, then multiplies by the current to get the drop in volts. The percent is the drop divided by the supply voltage times one hundred, and the 5 percent limit is five percent of the supply voltage. The American wire gauge article shows how wire size is named in another system, and the same physics applies whatever the naming.
Once the drop is worked out, the tool compares the percent with the 5 percent limit and gives a plain verdict. Because the maths runs on your device, nothing is uploaded and nothing is stored. The tool assumes a steady resistive load and a single phase circuit at normal temperature. Real cables run warmer under load, which raises the resistance a little, so a result just inside the limit deserves the next size up.
Privacy
Your numbers never leave your browser. They are typed on your own device, the result is shown on your own screen, and nothing is sent to a server at any point. Close the tab and the numbers are gone.
That matters because cable runs and loads can belong to a job you have not quoted yet. This tool has no account, no upload, and no log, so your work stays private by design, not by promise.
Tips
A few small habits make the number you get back more useful and easier to trust.
- Measure the one way length: the tool doubles the length for the return wire, so type the distance from supply to load once, not the total wire in the run.
- Time your site visits: Time Duration Calculator measures how long a job or a test actually lasted, so the hours you plan match the hours you put in.
- Count the days to the install: Countdown Calculator tells you how many days are left until the cable is ordered or the job starts.
- Check the age of the existing cable: Age Calculator works out your exact age in years, months and days, and the same idea helps when you note how old an installation is.
- Go one size up when in doubt: a result just inside the 5 percent limit leaves no margin for warm cable or a heavier load later, so the next size up is cheap insurance.
A careful voltage drop calculation starts with the real load current and the real route length. Guessed lengths give guessed drops, so walk the route once and measure it properly.
More Tools For The Same Job
Ten more tools cover the jobs around this one, from the value of a resistor to the runtime of a battery.
- Ohm’s Law Calculator: if you know two of voltage, current and resistance, an Ohm’s law calculator finds the third in one step.
- Resistor Color Code Calculator: if a resistor shows coloured bands instead of printed numbers, a resistor colour code calculator reads its value and tolerance from the bands.
- Series Resistance Calculator: if several resistors sit in a row in one circuit, a series resistance calculator adds them into one total.
- Parallel Resistance Calculator: if several resistors sit side by side across the same two points, a parallel resistance calculator works out the lower total they give together.
- Capacitance Calculator: if a capacitor holds a charge at a voltage, a capacitance calculator links charge, capacitance and voltage.
- Electrical Power Calculator: if you want the watts a circuit uses, an electrical power calculator works it out from voltage and current.
- Battery Runtime Calculator: if a battery must run a load for a set time, a battery runtime calculator works out how long the charge lasts.
- Torque Calculator: if a motor turns a load, a torque calculator works out the turning force from the force and the lever arm.
- Force Calculator: if a mass must speed up or slow down, a force calculator works out the push needed from mass and acceleration.
- Power Converter: changes power between watts, kilowatts, horsepower and more, so a value from one datasheet matches the units in another.
FAQ
Short answers to the questions people ask most about voltage drop.
What Is An Acceptable Voltage Drop?
For most wiring work, 5 percent of the supply voltage is the limit to stay inside, and 3 percent is better for lighting and sensitive loads. A 230 volt supply allows 11.5 volts at 5 percent, while a 12 volt supply allows only 0.6 volts, which is why low voltage runs need much thicker cable.
Why Does Voltage Drop Grow With Length?
Every metre of wire adds a little resistance, and the drop is current times resistance. A longer run has more resistance, so the same current loses more voltage along it. That is why the fix for a long run is a thicker wire with less resistance per metre.
Does Voltage Drop Matter For 12 Volt Systems?
It matters far more. The percent limit is the same, but 5 percent of 12 volts is only 0.6 volts, so a small loss that would pass unnoticed at 230 volts can fail a 12 volt circuit. Camper, boat and solar 12 volt runs need short cables or thick wire.
Is Aluminium Cable Worse Than Copper?
For the same size, aluminium loses about 68 percent more voltage than copper, because its resistivity is higher. It still works well when the size is stepped up to match, and it costs less, so the choice is a trade between the price of the metal and the size of the cable.
Is My Data Saved Anywhere?
No. Your numbers are read in your browser and never sent to a server. There is no upload, no account, and no copy kept anywhere. Closing the tab removes everything.
Is Voltage Drop Calculator by TechnSols Free?
Yes, Voltage Drop Calculator by TechnSols is completely free to use. You can work out that cable voltage drop from the current as often as you need, with no account, no sign up, and no payment. The tool runs entirely in your browser, so there is nothing to install and you can use it whenever you need it.
Voltage drop is easy to miss and expensive to fix after the cable is in. Work it out first, pick the size that passes, and the load gets the voltage it was built for.